NEW QUESTION 10
Refer to the exhibit.
The EEM script is applied in the default VDC to collect the outputs during high CPU utilization on the Cisco Nexus 7000 Series Switch for all VDCs. Which configuration set must be added to the script to fix the issue?
- A. switch(config-apple)# event snmp 1.3.6.1.4.1.9.9.109.1.1.1.1.6.1 get-type exact entry-op ge entry-val 50 poll-interval 1 switch(config-apple)# action 0.2 cli enable switch(config-apple)# action 0.5 cli switchto vdc Core switch(config-apple)# action 0.8 cli switchto vdc Distribution
- B. switch(config-apple)# event snmp oid 1.3.6.1.4.1.9.9.109.1.1.1.1.6.1 get-type exact entry-op ge entry-val 50 poll-interval 1 switch(config-apple)# action 0.2 cli config t switch(config-apple)# action 0.5 cli switchto vdc Core switch(config-apple)# action 0.8 cli switchto vdc Distribution
- C. switch(config-apple)# event snmp oid 1.3.6.1.4.1.9.9.109.1.1.1.1.6.1 get-type exact entry-op ge entry-val 50 poll-interval 1 switch(config-apple)# action 0.2 cli enable switch(config-apple)# action 0.5 cli switchto vdc Core switch(config-apple)# action 0.8 cli switchto vdc Distribution
- D. switch(config-apple)# event snmp 1.3.6.1.4.1.9.9.109.1.1.1.1.6.1 get-type exact entry-op ge entry-val 50 poll-interval 1 switch(config-apple)# action 0.2 cli config t switch(config-apple)# action 0.5 cli switchto vdc Core switch(config-apple)# action 0.8 cli switchto vdc Distribution
Answer: C
Explanation:
Need exact snap shot to confirm the following.
The selection of is due to
SNMP command has the key word "oid".
The command "switchto vdc Core" show run in "enable" mode, not "config t" mode.
NEW QUESTION 11
Drag and drop the actions from the left onto the faults that they resolve on the right. Not all options are used.
Answer:
Explanation:
NEW QUESTION 12
Refer to the exhibit.
HSRP adjacency fails to form between Nexus7K-1 and Nexus7K-2. Which action should be taken to solve the problem?
- A. Configure the same HSRP priority between the two switches.
- B. Configure preempt on one of the switches in the HSRP group.
- C. Configure HSRP version 2 on Nexus7K-2.
- D. Configure the correct subnet mask on Nexus7K-1.
Answer: C
NEW QUESTION 13 
Refer to the exhibit. An upgrade operation fails with an error displayed. Which action resolves the issue?
- A. Allocate extra space on a flash drive to extract a kickstart image.
- B. Use a different kickstart image.
- C. Use a different system image.
- D. Allocate extra space on a flash drive to extract a system image.
Answer: C
Explanation:
Section: Management and Operations
Explanation/Reference: https://www.cisco.com/c/en/us/td/docs/switches/datacenter/nexus1000/sw/4_2_1_s_v_1_4_a/ troubleshooting/configuration/guide/n1000v_trouble/n1000v_trouble_5upgrade.html
NEW QUESTION 14
Refer to the exhibit.
An engineer is investigating a role mapping issue on a switch. The users report that they cannot view the IP addresses under the tenant "corp". Which action resolves the issue?
- A. Configure the correct secret password between the APIC and the RADIUS server.
- B. Add the updated avpair to include/corp/admin/
- C. Add the users to the RADIUS server.
- D. Update the UNIX ID.
Answer: A
NEW QUESTION 15
You have an ACI environment with three APICs, two spine switches, and four-leaf switches. You wipe and reboot all APICs first then leaf and spine switches one-by-one and successfully go through the Initial Setuo dialogue on the APIC 1 CIMC KVM console. When you log in to the APIC1 WebGUI, you notice that you do not see any directly connected leaf switches being discovered under Fabric > Inventory > Fabric Membership. What is the cause of the issue?
- A. The same Fabric Name value should be used before after wiping all devices.
- B. The leaf nodes were not erased properly, which caused a fabric parameters mismatch with the APIC1.
- C. You forgot to enter the TEP Pool value during the Initial Setup dialogue on APIC1.
- D. Rebooting the APICs and the leaf and spine switches after wiping them is not required.
Answer: C
NEW QUESTION 16
During a boot process of a Cisco UCS C-Series Rack Server, an engineer receives a "No Signal" message from the vKVM and physical connection. Which set of steps resolves the issue?
- A. 1- Power off the server and disconnect the power cord
2- Confirm that all cards are property seated
3- Connect the power cord and power on the server - B. 1- Disconnect the power cord
2- Confirm that all cards are properly seated
3- Connect the power cord - C. 1- Disconnect the power cord
2- Confirm that all cards are property seated
3- Connect the power cord and power on the server - D. 1- Power off the server and disconnect the power cord
2- Confirm that all cards are available
3- Connect the power cord and power on the server
Answer: A
Explanation:
Explanation
https://www.cisco.com/c/en/us/td/docs/unified_computing/ucs/c/ts/guide/b_C-Series_Troubleshooting_Guide.pd
NEW QUESTION 17 
Refer to the exhibit. An engineer is investigating a role mapping issue on a switch. The users report that they cannot view the IP addresses under the tenant "corp". Which action resolves the issue?
- A. Configure the correct secret password between the APIC and the RADIUS server.
- B. Add the updated avpair to include/corp/admin/
- C. Add the users to the RADIUS server.
- D. Update the UNIX ID.
Answer: A
Explanation:
Section: Automation
NEW QUESTION 18
DRAG DROP
Drag and drop the Cisco UCS SNMP fault types from the left onto the correct issues on the right.
Select and Place:
Answer:
Explanation:
Section: Compute Platforms
NEW QUESTION 19 
Refer to the exhibit. The vPC between switch1 and switch2 does not work. Which two actions resolve the problem? (Choose two.)
- A. Configure one of the switches as primary for the vPC.
- B. Activate VLANs on the vPC.
- C. Configure the IP address on the interface.
- D. Match the vPC domain ID between the two devices.
- E. Correct the configuration of the vPC peer link and the vPC peer keepalive.
Answer: B,D
Explanation:
Section: Network
NEW QUESTION 20
Refer to the exhibit.
The EEM script fails to send an SNMP trap when a user attempts to enter configuration mode. Which configuration is missing from the script?
- A. IP address of the SNMP server
- B. event statement
- C. policy-default action statement
- D. event-default action statement
Answer: A
NEW QUESTION 21
An engineer is troubleshooting issues in Cisco UCS Director. Drag and drop the possible causes from the left onto the correct issues on the right.
Answer:
Explanation:
NEW QUESTION 22 
Refer to the exhibit. The EEM script is applied in the default VDC to collect the outputs during high CPU utilization on the Cisco Nexus 7000 Series Switch for all VDCs. Which configuration set must be added to the script to fix the issue?
- A. switch(config-applet)# event snmp 1.3.6.1.4.1.9.9.109.1.1.1.1.6.1 get-type exact entry-op ge entry-val
50 poll-interval 1
switch(config-applet)# action 0.2 cli config t
switch(config-applet)# action 0.5 cli switchto vdc Core
switch(config-applet)# action 0.8 cli switchto vdc Distribution - B. switch(config-applet)# event snmp oid 1.3.6.1.4.1.9.9.109.1.1.1.1.6.1 get-type exact entry-op ge entry-val 50 poll-interval 1 switch(config-applet)# action 0.2 cli config t switch(config-applet)# action 0.5 cli switchto vdc Core switch(config-applet)# action 0.8 cli switchto vdc Distribution
- C. switch(config-applet)# event snmp 1.3.6.1.4.1.9.9.109.1.1.1.1.6.1 get-type exact entry-op ge entry-val
50 poll-interval 1
switch(config-applet)# action 0.2 cli enable
switch(config-applet)# action 0.5 cli switchto vdc Core
switch(config-applet)# action 0.8 cli switchto vdc Distribution - D. switch(config-applet)# event snmp oid 1.3.6.1.4.1.9.9.109.1.1.1.1.6.1 get-type exact entry-op ge entry-val 50 poll-interval 1 switch(config-applet)# action 0.2 cli enable switch(config-applet)# action 0.5 cli switchto vdc Core switch(config-applet)# action 0.8 cli switchto vdc Distribution
Answer: D
Explanation:
Section: Automation
Explanation/Reference: https://community.cisco.com/t5/networking-documents/eem-script-on-nexus-7000-switches-to- monitor-cpu-utilization/ta-p/3120112
NEW QUESTION 23
Drag and drop the Cisco UCS SNMP fault types from the left onto the correct issues on the right.
Answer:
Explanation:
NEW QUESTION 24
Refer to the exhibit.
The HSRP configuration in the exhibit fails to function. Which action resolves this issue?
- A. Configure HSRP version 2.
- B. Set the MTU to 1500 bytes.
- C. Configure the same HSRP group on both devices.
- D. Enable IP redirects.
Answer: D
NEW QUESTION 25
A customer configures HSRP between two data centers that are interconnected with OTV. The configuration succeeds, but traffic between two ESXi virtual hosts on the same site is routed suboptimally through the OTV overlay. Which two actions optimize the traffic? (Choose two.)
- A. Filter HSRP by using a Layer 2 MAC-list on the OTV edge devices.
- B. Filter HSRP traffic by using a Layer 3 VACL on the OTV edge devices.
- C. Filter HSRP by using a Layer 2 MAC-list on the ESXi vSwitch.
- D. Disable first-hop redundancy.
- E. Filter HSRP traffic by using a Layer 3 VACL on the ESXi vSwitch.
Answer: B,D
Explanation:
Section: Network
NEW QUESTION 26
A Fibre Channel interface on a Cisco Nexus 5000 Series Switch receives bit errors, and the switch disables the interface. A temporary workaround must be implemented before the root cause is identified. Which action does an engineer take to prevent this issue from reoccurring?
- A. Change the SFP to operate at 4 Gbps instead of 2 Gbps.
- B. Run the switchport ignore bit-errors command on the interface.
- C. Verify that the SFPs are supported.
- D. Run the shutdown and then no shutdown command on the interface.
Answer: B
Explanation:
Section: Storage Network
Explanation
NEW QUESTION 27
A firmware upgrade on a fabric interconnect fails. A bootflash contains a valid image. Drag and drop the recovery steps from the left onto the correct order on the right.
Answer:
Explanation:
NEW QUESTION 28
......