NEW QUESTION # 22
Which I/O module(s) supports Full Switch and SmartFabric operating modes?

  • A. MX9116 and MX7116n
  • B. MX9116n only
  • C. MX9116n and MX5108n
  • D. MX5108 and MX5016s

Answer: C


NEW QUESTION # 23
On which generation of server was the BOSS-N1 controller introduced?

  • A. 14G
  • B. 16G
  • C. 15G

Answer: B


NEW QUESTION # 24
What are the port specifications of the MX8116n FEM?

  • A. Two QSFP56-DD interfaces 16 internal 100 GbE server-facing or 8 internal 25 GbE server-facing
  • B. Four QSFP56-DD interfaces 8 internal 100 GbE server-facing or 16 internal 25 GbE server-facing
  • C. Four QSFP56-DD interfaces 16 internal 100 GbE server-facing or 8 internal 25 GbE server-facing
  • D. Two QSFP56-DD uplink ports 8 internal 100 GbE server-facing or 16 internal 25 GbE server-facing

Answer: D


NEW QUESTION # 25
A system administrator must assign six of the MX5016s drives to a single MX750c compute node.
Which assignment mode accomplishes this task?

  • A. Multiple-assigned storage configuration
  • B. Drive-assigned storage configuration
  • C. PERC-assigned storage configuration
  • D. Enclosure-assigned storage configuration

Answer: B


NEW QUESTION # 26
What are the required components for a PowerEdge MX7000 Minimum to POST configuration?

  • A. Two power supply units
    One compute sled
    One input output module
    Two management modules
    Five front fans and four rear fans
  • B. Two power supply units
    One compute sled
    One input output module
    One management module
    Four front and five rear fans
  • C. One power supply unit
    One compute sled
    One input output module
    One management module
    Two front fans and two rear fans

Answer: C


NEW QUESTION # 27
A technician replaces a failed Management Module in an MX7000 chassis group. After the technician leaves the site, the administrator reports that the lead chassis is no longer able to communicate with its members.
How can OME-M be used to confirm the cabling configuration?

  • A. View the health status of the lead Chassis Management Module
  • B. View the I/O module topology map from the lead chassis
  • C. View the health status of the lead Chassis Management ports
  • D. View the topology map from the Group Lead

Answer: C


NEW QUESTION # 28
What type of power cord connects to the PSU side of a PowerEdge MX7000?

  • A. C15
  • B. C15
  • C. C21
  • D. C13

Answer: C


NEW QUESTION # 29
A system administrator is designing a solution for a customer who will be purchasing a large number of PowerEdge MX7000 chassis. For ease of management, they would like to have the least number of chassis management groups as possible.
What is the maximum number of MX7000 chassis that are supported in a multi-chassis management group?

  • A. 0
  • B. 1
  • C. 2
  • D. 3

Answer: C


NEW QUESTION # 30
A company receives their first MX7000 chassis. They connect all the provided power supply cables into two different PDUs on different power grids for redundancy. Each of the six power supplies is cabled and has green LEDs. One Management Module is present along with all system fans. Grid redundancy is configured as the power redundancy mode.
The chassis is fully populated with six compute sleds and one IOM but only two of the six sleds will power on.
What is the possible reason for this issue?

  • A. An additional IOM is required to power on and manage the remaining sleds.
  • B. Mixed high line and low line AC inputs in the same chassis is not supported.
  • C. Power supply unit redundancy policy was not used.
  • D. Two Management Modules are required to power on the populated chassis.

Answer: C


NEW QUESTION # 31
A PowerEdge MX7000 chassis was ordered with a factory-generated password. The customer needs to reset the PowerEdge MX7000 chassis configuration using the RACADM racresetcfg command.
What login credentials will the customer need to use to log on after running the command?

  • A. admin / calvin
  • B. root / calvin
  • C. root / password found on luggage tag
  • D. admin / password found on luggage tag

Answer: C


NEW QUESTION # 32
An administrator is connecting two MX840c to an MX5016s. The MX5016s is configured in Enclosure Assigned mode.
What should the requirements of this mode be to avoid configuration issues?

  • A. MX745P with no OS restrictions
  • B. MX745P with a cluster aware OS
  • C. HBA330MMZ with a cluster aware OS
  • D. HBA330MMZ with no OS restrictions

Answer: C


NEW QUESTION # 33
What is the minimum required HW configuration on the PowerEdge MX840c to POST?

  • A. 1 processor in socket CPU1
    1 memory module installed in socket A1
    1 mezzanine card installed in Mezz A1 slot
  • B. 1 processor in socket CPU2
    1 memory module installed in socket B1
    1 mezzanine card installed in Mezz B1 slot
  • C. 1 processor in any CPU socket
    1 memory module installed in any socket
    1 mezzanine card installed in any Mezz slot
  • D. 1 processor in each CPU socket
    1 memory module installed per CPU socket
    1 mezzanine card installed per CPU Mezz slot

Answer: A


NEW QUESTION # 34
A server administrator wants to configure RAID on drives that are assigned to a compute sled.
Which interface can be used to complete the task?

  • A. Storage sled assignment
  • B. OIDC
  • C. iDRAC
  • D. RAID Controller settings

Answer: C


NEW QUESTION # 35
A system administrator must obtain the correct rail and cable management to install a newly purchased MX7000 chassis into a rack.
What type of rail and cable management is supported?

  • A. Static rail with cable management arm
  • B. Sliding rail with cable management arm
  • C. Static rail with strain relief bar
  • D. Sliding rail with strain relief bar

Answer: C


NEW QUESTION # 36
Which SmartFabric Services Engine component is responsible for managing requested changes for the specific switching node?

  • A. Fabric Agent
  • B. SFS Controller
  • C. External Fabric Manager

Answer: A


NEW QUESTION # 37
An administrator has installed the iDRAC Service Module in the OS on a compute sled, they are unable to use its features in the iDRAC web GUI.
What is the likely cause of this issue?

  • A. OS and iDRAC are configured on different networks
  • B. iDRAC Express license is installed
  • C. Installed OS is not supported
  • D. OS to iDRAC pass-through feature is not enabled in the iDRAC

Answer: D


NEW QUESTION # 38
What is a characteristic of MX7000 networking in Scalable Fabric Mode?

  • A. Available on MX9116n FSE and MX7116n FEM but not on the MX5108n.
  • B. Layer 2 bridging is disabled be default and interfaces must join a bridge domain (VLAN) before being to forward frames.
  • C. All switch interfaces are assigned to VLAN 1 by default and are in the same Layer 2 bridge domain.
  • D. Enabled by default, all switch-specific OS10EE capabilities are available.

Answer: A


NEW QUESTION # 39
......

Focus on D-PEMX-DY-23 All-in-One Exam Guide For Quick Preparation: https://www.updatedumps.com/EMC/D-PEMX-DY-23-updated-exam-dumps.html

Practice To D-PEMX-DY-23 - UpdateDumps Remarkable Practice On your Dell PowerEdge MX Modular Deploy 2023 Exam Exam: https://drive.google.com/open?id=1MAAXSORagQVQH_lclVWY24-xVcjUqmj3