NEW QUESTION # 23
What are two requirements to achieve 100 GbE network speeds for a compute sled?
(Select 2)

  • A. Quad-port NIC
  • B. MX7116n
  • C. Z9432F-ON
  • D. Dual-port NIC
  • E. MX9116n

Answer: A,E


NEW QUESTION # 24
During the installation of a PowerEdge MX7000, the implementation engineer notices the PSU health indicator stay on for one second, blink five times, then shut off.
What is the issue?

  • A. There is a PSU mismatch.
  • B. There is no power to the PSU.
  • C. The PSU is faulty.
  • D. The PSU is performing firmware updates.

Answer: A


NEW QUESTION # 25
What is the minimum required HW configuration on the PowerEdge MX840c to POST?

  • A. 1 processor in socket CPU2
    1 memory module installed in socket B1
    1 mezzanine card installed in Mezz B1 slot
  • B. 1 processor in each CPU socket
    1 memory module installed per CPU socket
    1 mezzanine card installed per CPU Mezz slot
  • C. 1 processor in any CPU socket
    1 memory module installed in any socket
    1 mezzanine card installed in any Mezz slot
  • D. 1 processor in socket CPU1
    1 memory module installed in socket A1
    1 mezzanine card installed in Mezz A1 slot

Answer: D


NEW QUESTION # 26
Which two-socket PowerEdge sled can support up to eight E3.s NVMe Gen 5 SSD drives?

  • A. MX840c
  • B. MX760c
  • C. MX750c
  • D. MX740c

Answer: B


NEW QUESTION # 27
What are two considerations when adding an MX760c in a chassis running OME-M firmware earlier than v2.0?
(Select 2)

  • A. If the iDRAC of the existing sleds is not at a supported level, ATMOS cannot calculate the maximum cooling.
  • B. All the fans on the PowerEdge MX7000 must be Silver Grade.
  • C. If the MX760c is not a thermally challenged system, the sled is going to run as designed.
  • D. If the MX760c is a thermally challenged system, the maximum supported ambient temperature cannot be reduced.

Answer: A,D


NEW QUESTION # 28
What types of network shares are supported for hosting the firmware catalog for a PowerEdge MX7000 chassis?

  • A. SMB, SFTP, NFS, and FTP
  • B. SCP, FTP, NFS, and HTTPS
  • C. NFS, CIFS, HTTP, and HTTPS
  • D. HTTP, HTTPS, FTP, and SFTP

Answer: C


NEW QUESTION # 29
An administrator is asked to install and power on a new MX740c sled in a PowerEdge MX7000 chassis. The administrator inserts the sled and presses the power button. The power button LED is pulsating green. After a short time, the power button turns to solid green and the server turns on.
What operation was in progress when the power button was pulsating green?

  • A. Management Module was updating its component inventory
  • B. Lifecycle Controller was taking firmware inventory
  • C. IOM was booting
  • D. iDRAC was booting

Answer: D


NEW QUESTION # 30
Which SmartFabric Services Engine component is responsible for managing requested changes for the specific switching node?

  • A. External Fabric Manager
  • B. SFS Controller
  • C. Fabric Agent

Answer: C


NEW QUESTION # 31
What is the minimum OME-M version required to use ATMOS?

  • A. 2.10.00
  • B. 1.40.00
  • C. 2.00.00
  • D. 1.60.50

Answer: C


NEW QUESTION # 32
What is a function of the Fabric Resources Director (FReD)?

  • A. Critical temperature monitoring
  • B. Providing QuickSync 2 feature
  • C. Hosting OME-M interface
  • D. SAS Expander routing for Fabric C

Answer: A


NEW QUESTION # 33
What is a benefit of SmartFabric Services Mode?

  • A. Load balancing for management layers
  • B. Load balancing for application layers
  • C. Automatic detection of packet collisions
  • D. Topology validation and self-healing

Answer: A


NEW QUESTION # 34
Which two actions are possible using the Chassis Deployment Wizard?
(Select 2)

  • A. The firmware catalog can be configured using the FTP protocol.
  • B. The LCD pin can be configured.
  • C. The network I/O Module password can be configured.
  • D. The administrator can use an existing chassis profile to configure the chassis.

Answer: A,D


NEW QUESTION # 35
What compute sled model best supports the following requirements?
4 Node Database Cluster Heavy transactional workload 16 Processors
24 TB of DDR4 Memory
40 TB of Disk Space Maximum of 200,000 IOPS

  • A. 4 x MX840C 16 Processors
    24 TB of DDR4 Memory
    40 TB of Disk Space based on SAS SSD Drives
  • B. 8 x MX740C 16 Processors
    16 TB of DDR4 Memory
    50 TB of Disk Space based on SAS SSD Drives
  • C. 8 x MX750C 16 Processors
    16 TB of DDR4 Memory
    45 TB of Disk Space based on NVMe Drives
  • D. 4 x MX840C 16 Processors
    24 TB of DDR4 Memory
    40 TB of Disk Space based on NVMe Drives

Answer: D


NEW QUESTION # 36
Refer to the exhibit.

A customer recently replaced all the dual-port network cards in mezzanine A with quad-port network cards across all 16 PowerEdge MX740c sleds in the two-chassis configuration. The customer can only access half of the network ports, even though the quad-port cards are visible in the iDRAC.
What actions are required to resolve the problem?

  • A. Reseat all the switches.
    Adjust the switch configuration to use the new ports.
  • B. Reboot the switches.
    Adjust the switch configuration to use the new ports.
  • C. Do a virtual reseat of all the MX740c sleds.
    Update the firmware on all the quad port network cards.
    Adjust the switch configuration to use the new ports.
  • D. Install a new 200G cable from port 3 on the MX7116n in chassis 2 slot A1 into port 19 on the MX9116n in chassis 1 slot A1.
    Do the same for the switches in slots A2.
    Adjust the switch configuration to use the new ports.

Answer: D


NEW QUESTION # 37
What is a valid option when resetting iDRAC to factory defaults?

  • A. Preserve network and storage settings
  • B. Preserve storage and user settings
  • C. Preserve identity and network settings
  • D. Preserve user and network settings

Answer: D


NEW QUESTION # 38
Which VLAN is reserved for internal switch communication?

  • A. 0
  • B. 1
  • C. 2
  • D. 3

Answer: A


NEW QUESTION # 39
Which section of the PowerEdge MX7000 chassis provides a structure for mounting PSUs and sleds?

  • A. Main Chassis
  • B. Management Module slot
  • C. Rear Tub
  • D. Main Distribution Board

Answer: A


NEW QUESTION # 40
An administrator is mapping the drives of an MX5016s. The disk must be split in groups among multiple compute sled slots.
Which storage configuration must be used?

  • A. Drive-Assigned mode
  • B. Split-Assigned mode
  • C. Enclosure-Assigned mode

Answer: A