NEW QUESTION # 23
What are two requirements to achieve 100 GbE network speeds for a compute sled?
(Select 2)
- A. Quad-port NIC
- B. MX7116n
- C. Z9432F-ON
- D. Dual-port NIC
- E. MX9116n
Answer: A,E
NEW QUESTION # 24
During the installation of a PowerEdge MX7000, the implementation engineer notices the PSU health indicator stay on for one second, blink five times, then shut off.
What is the issue?
- A. There is a PSU mismatch.
- B. There is no power to the PSU.
- C. The PSU is faulty.
- D. The PSU is performing firmware updates.
Answer: A
NEW QUESTION # 25
What is the minimum required HW configuration on the PowerEdge MX840c to POST?
- A. 1 processor in socket CPU2
1 memory module installed in socket B1
1 mezzanine card installed in Mezz B1 slot - B. 1 processor in each CPU socket
1 memory module installed per CPU socket
1 mezzanine card installed per CPU Mezz slot - C. 1 processor in any CPU socket
1 memory module installed in any socket
1 mezzanine card installed in any Mezz slot - D. 1 processor in socket CPU1
1 memory module installed in socket A1
1 mezzanine card installed in Mezz A1 slot
Answer: D
NEW QUESTION # 26
Which two-socket PowerEdge sled can support up to eight E3.s NVMe Gen 5 SSD drives?
- A. MX840c
- B. MX760c
- C. MX750c
- D. MX740c
Answer: B
NEW QUESTION # 27
What are two considerations when adding an MX760c in a chassis running OME-M firmware earlier than v2.0?
(Select 2)
- A. If the iDRAC of the existing sleds is not at a supported level, ATMOS cannot calculate the maximum cooling.
- B. All the fans on the PowerEdge MX7000 must be Silver Grade.
- C. If the MX760c is not a thermally challenged system, the sled is going to run as designed.
- D. If the MX760c is a thermally challenged system, the maximum supported ambient temperature cannot be reduced.
Answer: A,D
NEW QUESTION # 28
What types of network shares are supported for hosting the firmware catalog for a PowerEdge MX7000 chassis?
- A. SMB, SFTP, NFS, and FTP
- B. SCP, FTP, NFS, and HTTPS
- C. NFS, CIFS, HTTP, and HTTPS
- D. HTTP, HTTPS, FTP, and SFTP
Answer: C
NEW QUESTION # 29
An administrator is asked to install and power on a new MX740c sled in a PowerEdge MX7000 chassis. The administrator inserts the sled and presses the power button. The power button LED is pulsating green. After a short time, the power button turns to solid green and the server turns on.
What operation was in progress when the power button was pulsating green?
- A. Management Module was updating its component inventory
- B. Lifecycle Controller was taking firmware inventory
- C. IOM was booting
- D. iDRAC was booting
Answer: D
NEW QUESTION # 30
Which SmartFabric Services Engine component is responsible for managing requested changes for the specific switching node?
- A. External Fabric Manager
- B. SFS Controller
- C. Fabric Agent
Answer: C
NEW QUESTION # 31
What is the minimum OME-M version required to use ATMOS?
- A. 2.10.00
- B. 1.40.00
- C. 2.00.00
- D. 1.60.50
Answer: C
NEW QUESTION # 32
What is a function of the Fabric Resources Director (FReD)?
- A. Critical temperature monitoring
- B. Providing QuickSync 2 feature
- C. Hosting OME-M interface
- D. SAS Expander routing for Fabric C
Answer: A
NEW QUESTION # 33
What is a benefit of SmartFabric Services Mode?
- A. Load balancing for management layers
- B. Load balancing for application layers
- C. Automatic detection of packet collisions
- D. Topology validation and self-healing
Answer: A
NEW QUESTION # 34
Which two actions are possible using the Chassis Deployment Wizard?
(Select 2)
- A. The firmware catalog can be configured using the FTP protocol.
- B. The LCD pin can be configured.
- C. The network I/O Module password can be configured.
- D. The administrator can use an existing chassis profile to configure the chassis.
Answer: A,D
NEW QUESTION # 35
What compute sled model best supports the following requirements?
4 Node Database Cluster Heavy transactional workload 16 Processors
24 TB of DDR4 Memory
40 TB of Disk Space Maximum of 200,000 IOPS
- A. 4 x MX840C 16 Processors
24 TB of DDR4 Memory
40 TB of Disk Space based on SAS SSD Drives - B. 8 x MX740C 16 Processors
16 TB of DDR4 Memory
50 TB of Disk Space based on SAS SSD Drives - C. 8 x MX750C 16 Processors
16 TB of DDR4 Memory
45 TB of Disk Space based on NVMe Drives - D. 4 x MX840C 16 Processors
24 TB of DDR4 Memory
40 TB of Disk Space based on NVMe Drives
Answer: D
NEW QUESTION # 36
Refer to the exhibit.
A customer recently replaced all the dual-port network cards in mezzanine A with quad-port network cards across all 16 PowerEdge MX740c sleds in the two-chassis configuration. The customer can only access half of the network ports, even though the quad-port cards are visible in the iDRAC.
What actions are required to resolve the problem?
- A. Reseat all the switches.
Adjust the switch configuration to use the new ports. - B. Reboot the switches.
Adjust the switch configuration to use the new ports. - C. Do a virtual reseat of all the MX740c sleds.
Update the firmware on all the quad port network cards.
Adjust the switch configuration to use the new ports. - D. Install a new 200G cable from port 3 on the MX7116n in chassis 2 slot A1 into port 19 on the MX9116n in chassis 1 slot A1.
Do the same for the switches in slots A2.
Adjust the switch configuration to use the new ports.
Answer: D
NEW QUESTION # 37
What is a valid option when resetting iDRAC to factory defaults?
- A. Preserve network and storage settings
- B. Preserve storage and user settings
- C. Preserve identity and network settings
- D. Preserve user and network settings
Answer: D
NEW QUESTION # 38
Which VLAN is reserved for internal switch communication?
- A. 0
- B. 1
- C. 2
- D. 3
Answer: A
NEW QUESTION # 39
Which section of the PowerEdge MX7000 chassis provides a structure for mounting PSUs and sleds?
- A. Main Chassis
- B. Management Module slot
- C. Rear Tub
- D. Main Distribution Board
Answer: A
NEW QUESTION # 40
An administrator is mapping the drives of an MX5016s. The disk must be split in groups among multiple compute sled slots.
Which storage configuration must be used?
- A. Drive-Assigned mode
- B. Split-Assigned mode
- C. Enclosure-Assigned mode
Answer: A
NEW QUESTION # 41
......
100% Passing Guarantee - Brilliant D-PEMX-DY-23 Exam Questions PDF: https://www.updatedumps.com/EMC/D-PEMX-DY-23-updated-exam-dumps.html